China Industrial Metering Equipment Online Market
|
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Intelligent Power Quality Analysis For Waveform Sampling , GPS Synchronization
Product Profile
ARZ®-3L power quality analyzer is an integrated monitoring, analyzing and controlling device that offers electrical parameter metering, harmonics metering and analysis, waveform sampling, measurement of Voltage swell, dip, interrupt, Voltage unbalanced ratio, demand, fault record, event record, data record. ARZ®-3L can monitor and detect if the power quality fulfills IEC and EN standard.
ARZ®-3L fulfils all the important requirements of IEC 61000-4-30 Class A standard.ARZ®-3L can work with our power quality monitoring and management software to provide energy management solutions for enterprises. With its strong networking capability, ARZ®-3L can display and record all the data records on the interactive trend chart. A data report can be formed periodically. The report can be used for fault analysis, statistics, and real time monitoring purpose.
Application
>Power quality detection and management
>Disturbance analysis, faults analysis, device pre-maintenance
>Long term record and analysis
>Power loads analysis
>Energy consumption evaluation and analysis
>Utilizing GPS synchronization to analyze the relevance between events in different locations
>Applied scope: Single phase and 3phase electrical power system
Main functions
Measured scope |
1P2W,3P3W,3P4W,3P5W programmable |
Basic parameters measurement: |
Voltage, Current (including, negative, zero sequence Current), frequency, power factor, active power, reactive power, apparent power, active energy, reactive energy, energy demand, Current/Voltage unbalance ratio, energy demand. |
Harmonics monitoring indicator |
Harmonics (2nd to 127th), including total Voltage/Current harmonic distortion ratio, each harmonic ratio, magnitude, phase angle, active power, reactive power, etc. Inter-harmonics(1.5 to 126.5) Voltage flicker quickly (Pst), flicker slowly (Plt), swell, dip, interrupt and transient change (optional). Surging Current (optional, only valid when matching with power clamp sensor outside) |
Oscillograph, waveshape faults record |
Real time display Voltage and Current waveform. Form the Voltage waveform and faults record on the occasion of harmonic component overlimit, harmonic distortion overlimit, R.M.S Voltage overlimit, short circuit fault etc. |
Parameter record, event alarm |
The built-in memory can record all the data that is needed, with the capacity of 32GB. |
Power quality reliability detection |
Display power quality detection result. |
Multi communication protocol |
Modbus-RTU,TCP/IP, etc. |
Help/guide function |
User-friendly |
Display and operate function |
TFT true color LCD: resolution 640×480,65535 colors; touch screen and key dual operation mode; wave display support scaling operation. |
Other functions |
Online statistics; GPS synchronization; Network synchronization |
Event alarming |
Event triggered alarming function through e-mail and SMS. |
Measurement Accuracy
U, I rms value: 0.1%
U, I peak value, peak factor: 2%
Flicker: 5%
Voltage unbalanced and Current unbalanced: 0.2%
Frequency: ±0.002Hz
Power factor: ±0.002
Power: 0.1%
Energy: Active energy 0.05% IEC60687:1992 (GB/T17883-1999)
Reactive energy 0.05% IEC61268 (1995) (GB/T17882-1999)
Harmonics: IEC61000-4-30 class A
Inter-harmonics: IEC61000-4-30 class A
Interface