Quick Detail:

 

· 4–20 mA loop-powered

· Operating range to 39ft (12m)

· Accrucay:

o ±0.1" (2.5 mm) for less than 3.3ft measurements

o ±0.25% for over 3.3ft measurements

· Sealed rugged UPVC housing

· Corrosion resistant PVDF wetted material

· Simple set-up and operation

· Minimal maintenance after installed

· Low cost of installation and commissioning

· Automatic temperature compensation

 

 

Description:

 

The Rosemount 3107 / 3108 Ultrasonic Level and Flow Transmitters are based on ultrasonic technology. Ultrasonic pulse signals are transmitted and reflected from the liquid surface. The transmitter ‘listens' for reflected signals (echoes) and measures the time-delay between transmitting and receiving. The distance to the liquid surface is automatically calculated using the computed time-delay. The level measurement (Bottom Reference minus Distance) is sent through the 4–20 mA and HART output.

 

The 3107 has an integrated sensor for automatically compensating the Distance for temperature effects.

The 3108 has a factory fitted remote temperature sensor to continuously measure the air temperature around the transmitter. It then computes the speed of sound in air, automatically compensating Distance for temperature effects.

 

 

Applications:

 

Applications for the Rosemount 3107 / 3108 Ultrasonic Level and Flow Transmitters include:

· Storage tank levels

· Open channel flow

· Effluent pits

· Reservoir level

· Buffer tanks

· Filter bed level

 

 

Specifications:

 

Key Specifications
Measurement Principle Ultrasonic, time-of-flight
Measuring Range

1 to 39 ft (0,3 to 12 m) for 3107

1 to 11 ft (0,3 to 3,3 m) for 3108

Instrument Accuracy ± 0.25% of distance or
± 0.1 in. (2.5 mm) < 3.3 ft (1 m) under reference conditions*
Level Resolution Better than 1/16 in. (1 mm)
Blanking Distance 12 in. (0.3 m)
Output 4-20mA with superimposed digital HART® communication
Temperature/Pressure Rating Refer to the Product Data Sheet
Hazardous Location Approvals Intrinsic Safety (ATEX, CSA, IECEx, and FM)
MCERTS Approval The 3108 is MCERTS certified when used with aRosemount 3490 Series Control Unit
Output Variables Level, Distance, Volume, and Open Channel Flow
Enclosure UPVC housing and wetted material
Ingress Protection IP68 to 33 ft. (10 m)
Configuration Tools
bigPhoto
 Mr. Cui

Tel: 86-755-82714192
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

China Industrial Metering Equipment Online Market [China (Mainland)]


Business Type:Manufacturer
City: Shenzhen
Province/State: Guangdong
Country/Region: China (Mainland)

You May Like:

Product (114)